SPE0526S36RG

5-line esd protection array

器件类别:分立半导体    二极管   

厂商名称:擎力科技(SYNC POWER)

厂商官网:http://www.syncpower.com/

下载文档
器件参数
参数名称
属性值
厂商名称
擎力科技(SYNC POWER)
Reach Compliance Code
compliant
ECCN代码
EAR99
文档预览
SPE0526
5-Line ESD Protection Array
DESCRIPTION
The SPE0526 are designed by TVS bi-direction device that
is to protect sensitive electronics from damage or latch-up
due to ESD. They are designed for use in applications
where board space is at a premium. SPE0526 is
bidirectional devices that will protect up to five lines, and
may be used on lines where the signal polarities swing
above and below ground .
SPE0526 offer desirable characteristics for board level
protection including fast response time, low operating and
clamping voltage, and no device degradation.
SPE0526 may be used to meet the immunity requirements
of IEC 61000-4-2, level 4. The small SOT-363 package
makes them ideal for use in portable electronics such as
cell phones, PDA’s, notebook computers, and digital
cameras.
APPLICATIONS
Cellular Handsets and Accessories
Cordless Phone
PDA
Notebooks and Handhelds
Portable Instrumentation
Digital Cameras
MP3 Player
FEATURES
Transient protection for data lines to
IEC 61000-4-2 (ESD) ±15kV (air), ±8kV (contact)
IEC 61000-4-4 (EFT) 40A (5/50ns)
Protects five bidirectional I/O lines
Working voltage: 5V
Low leakage current
Low operating and clamping voltages
PIN CONFIGURATION ( SOT-363 )
PART MARKING
2007/04/27
Ver.1
Page 1
SPE0526
5-Line ESD Protection Array
ORDERING INFORMATION
Part Number
SPE0526S36RG
Week Code : A ~ Z( 1 ~ 26 ) ; a ~ z( 27 ~ 52 )
SPE0526S36RG : Tape Reel ; Pb – Free
Package
SOT-363
Part
Marking
EAYW
ABSOULTE MAXIMUM RATINGS
(T
A
=25
Unless otherwise noted)
Parameter
Peak Pulse Power ( tp = 8/20
μs
)
Maximum Peak Pulse Current ( tp = 8/20
μs
)
ESD per ICE 61000 – 4 – 2 (Air )
ESD per ICE 61000 – 4 – 2 (Contact )
Operating Junction Temperature
Storage Temperature Range
Lead Soldering Temperature
Symbol
Ppk
Ipp
Vpp
Vpp
T
J
T
STG
T
L
Typical
250
7
±15
±8
-55 ~ 150
-55 ~ 150
260 ( 10sec )
Unit
W
A
KV
KV
ELECTRICAL CHARACTERISTICS
(T
A
=25
Unless otherwise noted)
Parameter
Reverse Stand – Off
Voltage
Reverse Breakdown Voltage
Reverse Leakage Current
Reverse Leakage Current
Clamping Voltage
Clamping Voltage
Junction Capacitance
Symbol
V
RWM
V
BR
I
R
I
R
V
C
V
C
Cj
It = 1mA
V
RWM
= 5V , T=25℃
V
RWM
= 3V , T=25℃
Ipp = 1A , tp = 8/20
μs
Ipp = 7A , tp = 8/20
μs
Between I/O Pin and GND
V
R
= 0V , f = 1MHz
5
6
0.01
0.01
1
0.5
11.5
15
10
Conditions
Min.
Typ
Max.
5
Unit
V
V
μA
μA
V
V
pF
2007/04/27
Ver.1
Page 2
SPE0526
5-Line ESD Protection Array
TYPICAL CHARACTERISTICS
Clamping Voltage (Ipp = 1A , tp = 8/20
μs
)
Clamping Voltage (Ipp = 7A , tp = 8/20
μs
)
2007/04/27
Ver.1
Page 3
SPE0526
5-Line ESD Protection Array
TYPICAL CHARACTERISTICS
Fig 1 : Junction Capacitance V.S Reverse Voltage Applied
Fig 2 : Peak Plus Power V.S Exponential Plus Duration
Fig 3 : Relative Variation of Peal Plus Power V.S
Initial Junction Temperature
Fig 4 : Forward Voltage Drop V.S Peak Forward Current
2007/04/27
Ver.1
Page 4
SPE0526
5-Line ESD Protection Array
APPLICATION NOTE
Device Connection for Protection of Five Data Lines
SPE0526 is designed to protect up to five bidirectional data lines. The device is connected as follows:
1. Bidirectional protection of five I/O lines is achieved by connecting pins 1, 3, 4, 5, and 6 to the data lines. Pin 2
is connected to ground. The ground connection should be made directly to the ground plane for best results.
The path length is kept as short as possible to reduce the effects of parasitic inductance in the board traces.
Circuit Board Layout Recommendations for Suppression of ESD
Good circuit board layout is critical for the suppression of ESD induced transients. The following guidelines are
recommended:
1. Place the TVS near the input terminals or connectors to restrict transient coupling.
2. Minimize the path length between the TVS and the protected line.
3. Minimize all conductive loops including power and ground loops.
4. The ESD transient return path to ground should be kept as short as possible.
5. Never run critical signals near board edges.
6. Use ground planes whenever possible.
2007/04/27
Ver.1
Page 5